SYNOPSIS

       bkpupsd device


DESCRIPTION

       The bkpupsd program is a Simple Uninterruptible Power Source (UPS) dae-
       mon to control APC Back-UPS Pro. series.  When the power fails and goes
       out, the UPS daemon (upsd) shutdown the system cleanly.

       The  device is a serial port name connected to UPS. e.g.  /dev/cuaa0 or
       /dev/cuaa1, as a fully qualified device node under /dev.   If  Omitted,
       the device is assumed to be /dev/cuaa1 by default.

       The bkpupsd is designed to control UPS in dumb mode. Current specifica-
       tions are follows:

       UPS     When the power goes out, the UPS switches power source to  bat-
               tery  and signals the power went out by raising the serial port
               control line RNG.   If  battery  power  is  also  exhausted  or
               failed,  the UPS signals the battery low by lowering CTS.  When
               DTR is high and RNG goes high, the UPS induce itself  to  shut-
               down  mode.  In the shutdown mode the UPS stops supplying power
               to save the battery from overload and waits the recovery of the
               power.  (After the power returns, the system will restart auto-
               matically.)

       bkpupsd The upsd monitors the serial port, keeps  DTR  raised  and  RTS
               lowered.  When  the  upsd  sees  the  RNG  goes  high, runs the
               bkpups.failed (powerfail warning shell-script) and reports pow-
               erfailure  to syslog.  If the powerfailure continued for 5 min-
               utes, the upsd runs the bkpups.shudown (shutdown  shell-script)
               ,  reports to syslog and makes the UPS to sleep by raising RTS.
                The power recovered  within  5  minutes,  the  upsd  runs  the
               bkpups.restored (shell-script for power recovery) and continues
               to monitor the serial port for another powerfilure. In case the
               batter low is observed, the upsd runs the bkpups.battlow (emer-
               gency shutdown shell-script) immediately, reports to syslog and
               makes the UPS to sleep.


FILES

       /usr/local/libexec/bkpupsd/bkpups.failed
               Powerfailure  warning  Shell-script:  A  shell-script to inform
               users the power goes out and the  system  will  be  down  soon.
               (Warning only)
       /usr/local/libexec/bkpupsd/bkpups.shutdown
               Shutdown  Shell-script:  A  shell-script to shutdown the system
               cleanly.
       /usr/local/libexec/bkpupsd/bkpups.restored
               Power recovery Shell-script: A shell-script to inform users the
               power has been restored and system shutdown was canceled.
       /usr/local/libexec/bkpupsd/bkpups.battlow
               Emergency shutdown Shell-script: A shell-script to excute emer-
               gency halt for battery power failing.

       700"(because anyone who can run these scripts also get the privilage of
       shutdonw the system). bkpupsd requires to be run in root  privilage  to
       execute  the  shell-scripts.  The bkpupsd will be replaced with FreeBSD
       standard Alexis Yushin's upsd which is under development.


SEE ALSO

       upsd(8)



BUGS

       If the power recover after the shutdown script run, the system shutdown
       will not be canceled, auto-restart may not performed and the system may
       be halted until restart is invoked using reset switch.


AUTHOR

       Yoshifumi Watanabe <mwatts@edu1.tokyo-med.ac.jp>


HISTORY

       The bkpupsd appeared after FreeBSD 2.2.1R.




                                 July 12, 1997                      BKPUPSD(8)